Ammonia recovery from anaerobic digester centrate using onsite pilot scale bipolar membrane electrodialysis coupled to membrane stripping was written by Ferrari, Federico;Pijuan, Maite;Molenaar, Sam;Duinslaeger, Nick;Sleutels, Tom;Kuntke, Philipp;Radjenovic, Jelena. And the article was included in Water Research in 2022.Name: 4-Oxo-tempo This article mentions the following:
Ammonia recovery from centrate of an anaerobic digester was investigated using an onsite bipolar-electrodialysis (BP-ED) pilot scale plant coupled to two liquid/liquid membrane contactor (LLMC) modules. To investigate the process performance and robustness, the pilot plant was operated at varying current densities, load ratio (current to nitrogen loading), and in continuous and intermittent current (Donnan) mode. A higher load ratio led to higher total ammonium nitrogen (TAN, sum of ammonia and ammonium) removal efficiency, whereas the increase in the applied current did not have a significant impact the TAN removal efficiency. Continuous current application resulted in the higher TAN removal compared with the Donnan dialysis mode. The lowest specific energy consumption of 6.3 kWh kg-1N was recorded in the Donnan mode, with the load ratio of 1.4, at 200 L h-1 flowrate and c.d. of 75 A m-2. Lower energy demand observed in the Donnan mode was likely due to the lower scaling and fouling of the ion exchange membranes. Nevertheless, scaling and fouling limited the operation of the BP-ED stack in all operational modes, which had to be interrupted by the daily cleaning procedures. The LLMC module enabled a highly selective recovery of ammonia as ammonium sulfate ((NH4)2SO4), with the concentration of ammonia ranging from 19 to 33 gN L-1. However, the anal. of per- and polyfluoroalkyl substances (PFASs) in the obtained (NH4)2SO4 product revealed the presence of 212-253 ng L-1 of 6:2 fluorotelomer sulfonate (FTS), a common substitute of legacy PFAS. Given the very low concentrations of 6:2 FTS (i.e., < 2 ng L-1) encountered in the concentrated stream, 6:2 FTS was likely released from the Teflon-based components in the sulfuric acid dosage line. Thus, careful selection of the pilot plant tubing, pumps and other components is required to avoid any risks associated with the PFAS presence and ensure safe use of the final product as fertilizer. In the experiment, the researchers used many compounds, for example, 4-Oxo-tempo (cas: 2896-70-0Name: 4-Oxo-tempo).
4-Oxo-tempo (cas: 2896-70-0) belongs to piperidine derivatives.Piperidine is a key saturated heterocyclic scaffold found in several of the top-selling small molecule pharmaceuticals and natural alkaloids, with a diverse range of biological activities. The piperidine and polyhydroxylated indolizidine derivatives have shown to be promising 伪-glucosidase inhibitors. The former are analogs of DNJ with an improved 伪-glucosidase inhibitory profile than that of DNJ. Boisson et al.Name: 4-Oxo-tempo
Referemce:
Piperidine – Wikipedia,
Piperidine | C5H11N – PubChem